GENERAL DESCRIPTION
The VM02 retractable power tower by New VMR for the distribution of electricity and complementary services, such as water, compressed air, data transmission and audio systems, can also be used with the cover in rest position, using the special rubberized door for cable outlet.
The unit is composed of a stainless steel mechanical structure and a RBK 300 concrete containment box.
The manhole cover is made of stainless steel and is available as to fill or with an almond finishing.
Its opening is eased by a pivot partially removable from the lid surface and by the double gas actuator springs; while, its closing is guaranteed by a safety bronzed bayonet lock in AISI304 stainless steel operated by a square or triangular key.
The VM02 model comes in three different formats: the model 40×40, the model 50×50, the model 60×60 and the model 70×50.
For the specific technical description of each model download the document from the red box below.
Manhole covers available
Stainless steel* cover with 400KN almond finish
Stainless steel* cover with 250KN filling
* electro pickling and electropolishing with passivation of stainless steel treatment to finish and clean the covers from welding marks
TECHNICAL DETAILS
Structure
RBK concrete box
Structure made of AISI304 stainless steel
Structure made of AISI316L stainless steel (only on demand)
Connection system
Connection with junction box
Electrical specs
Voltage 230V/400V
Frequency from 50hz to 60hz
Standard protection of the sockets IP67 or IP68
Regulation EN 60947-1 and EN 61439
Additional equipment
Compressed air outlets
Audio / video connectors
RJ-data / video / telephone jacks
Water outlets / valves 1/2″ or 3/4″
Energy consumption meters
Water consumption meters
Prepaid system with rechargeable BADGE cards and CONTROL TOTEM
EQUIPMENT EXAMPLES
New VMR equips its flip lid units for the distribution of services with IP67 sockets.
Below you can see some examples of electrical configurations for the retractable power tower type VM02, model 40×40:
Equipment A: |
Equipment F: |
01 2P+E 16A CEE socket |
02 2P+E 16A interlocked sockets with fuse |
01 RCBO 1P+N 16A 6ka 0,03 |
01 3P+N+E 16A interlocked socket with fuse |
01 3P+N+E 32A CEE socket |
01 3P+N+E 32A interlocked socket with fuse |
01 RCBO 4x32A 6ka 0,03 |
01 heating kit |
01 heating kit |
|
|
Equipment G: |
Equipment B: |
03 2P+E 16A interlocked sockets with fuse |
02 2P+E 16A CEE sockets |
01 3P+N+E 16A interlocked socket with fuse |
02 RCBOs 1P+N 16A 6ka 0,03 |
01 heating kit |
01 3P+N+E 16A CEE socket |
|
01 RCBO 4x16A 6ka 0,03 |
Equipment H: |
01 heating kit |
04 2P+E 16A interlocked sockets with fuse |
|
01 heating kit |
Equipment C: |
|
03 2P+E 16A CEE sockets |
Equipment I: |
03 RCBOs 1P+N 16A 6ka 0,03 |
04 ball valves 1/2″ |
01 heating kit |
|
|
Equipment L: |
Equipment D: |
02 ball valves 1/2″ |
01 2P+E 32A CEE socket |
02 water meters |
01 RCBO 1P+N 32A 6ka 0,03 |
|
01 heating kit |
Equipment M: |
|
04 civil sockets |
Equipment E: |
04 SCHUKO sockets |
01 3P+N+E 32A CEE socket |
01 heating kit |
01 RCBO 4x32A 6ka 0,03 |
|
01 heating kit |
|
Below you can see some examples of electrical configurations for the retractable power tower type VM02, model 50×50:
Equipment A: |
Equipment F: |
04 2P+E 16A sockets |
03 2P+E 16A sockets |
04 RCBOs 1P+N 16A 6ka 0,03 |
03 RCBOs 1P+N 16A 6ka 0,03 |
01 ball valve 1/2″ (on the plate) |
01 3P+N+E 32A socket |
01 heating kit |
01 RCBO 4x32A 6ka 0,03 |
|
01 heating kit |
Equipment B: |
|
06 2P+E 16A sockets |
Equipment G: |
06 RCBOs 1P+N 16A 6ka 0,03 |
02 2P+E 16A sockets |
01 heating kit |
02 RCBOs 1P+N 16A 6ka 0,03 |
|
02 3P+N+E 32A sockets |
Equipment C: |
02 RCBOs 4x326A 6ka 0,03 |
02 2P+E 16A sockets |
01 heating kit |
02 RCBOs 1P+N 16A 6ka 0,03 |
|
01 3P+N+E 16A socket |
Equipment H: |
01 RCBO 4x16A 6ka 0,03 |
01 3P+N+E 63A socket with electrical interlock |
01 3P+N+E 32A socket |
01 RCBO 4x63A 6ka 0,03 |
01 RCBO 4x32A 6ka 0,03 |
01 heating kit |
01 heating kit |
|
|
Equipment I: |
Equipment D: |
02 2P+E 16A interlocked sockets |
03 2P+E 16A sockets |
02 RCBOs 1P+N 16A 6ka 0,03 |
03 RCBOs 1P+N 16A 6ka 0,03 |
01 3P+N+E 16A interlocked socket |
01 3P+N+E 16A socket |
01 RCBO 4x16A 6ka 0,03 |
01 RCBO 4x16A 6ka 0,03 |
01 heating kit |
01 heating kit |
|
|
Equipment L: |
Equipment D: |
01 heating kit |
02 2P+E 16A sockets |
02 RCBOs 1P+N 16A 6ka 0,03 |
02 RCBOs 1P+N 16A 6ka 0,03 |
01 3P+N+E 32A interlocked socket |
02 3P+N+E 16A sockets |
01 RCBO 4x32A 6ka 0,03 |
02 RCBOs 4x16A 6ka 0,03 |
01 heating kit |
01 heating kit |
|
|
Equipment M: |
|
04 2P+E 16A interlocked sockets |
|
04 RCBOs 1P+N 16A 6ka 0,03 |
|
01 heating kit |
Below you can see some examples of electrical configurations for the retractable power tower type VM02, model 60×60